Trouble shooting

Problem: Screen does not switch on

Possible causes
Possible solution

Poor electrical connection to the vehicle battery?

  • Check that the battery terminals are correctly fitted and have good contact.

  • Check that a good earth point has been selected.

  • The DYNCO 2.0 must be connected to the vehicle battery - a 12V booster is not sufficient.

Defective fuse?

  • Replace 30A fuse.

Problem: "Insufficient new oil" message

Possible causes
Possible solution

Too little oil in the fresh oil canister?

  • Fill the canister with new oil (2 litres more than the programmed quantity).

Problem: "Pump filling" message

Possible causes
Possible solution

Cables not connected?

  • Check the hydraulic connections of the appliance or the connections on the adapters.

Air in the DYNCO 2.0 circuit?

  • Vent the device as described under PRIMING.

  • Check the function of the pump using the TEST MODE.

Problem: "Pump filling" error (with PRE-FLUSH)

Possible causes
Possible solution

Additive tank is empty?

  • Fill the additive tank with the required amount of PRE-FLUSH.

Noises from the pump, like when a valve jams?

  • Vent the device as described under PRIMING.

  • Check the 3-way solenoid valve using the TEST MODE.

Problem: "Insufficient oil flow" error

Possible causes
Possible solution

Is the engine running?

  • Start and run the engine, set the selector lever to "P" and fit the brake servo if necessary.

Is the oil reservoir positioned correctly?

  • Check the position of the fresh and used oil canisters.

Adapter fitted correctly?

  • Check the mounting of the adapter (correct positioning, tightening torque...)

Gearbox flushing must be supported by "ADAP FLUX" (item no. 1002126)?

  • Check whether the adapters on the affected gearbox need to be supplemented with adapter 1002126.

  • Repeat flushing with 1002126 connected.

Oil level in the gearbox too low?

  • Check and top up if necessary, then try again.

Is it a gearbox classified as "low flow"?

  • Follow the procedure for gearboxes with low oil pressure LOW FLOW.

Is the DYNCO solenoid valve defective?

  • Check the solenoid valve using the TEST MODE.

Problem: "Oil drain" error

Possible causes
Possible solution

Voltage too low?

  • Check battery voltage.

The oil scales are not working?

  • Check the function of the scale using TEST MODE, replace the scale if necessary.

Problem: Printer error

Possible causes
Possible solution

Electrical connection to the printer?

  • Check the printer's plug connection, repair or replace defective cable if necessary.

Printer defective?

  • Replace printer (item no. 1002103)

Problem: "Tare not possible" error

Possible causes
Possible solution

Weight fluctuations / vibrations during calibration

  • Avoid touching the scales or containers during calibration.

  • Avoid shocks to the DYNCO 2.0.

The scales are not working?

  • Check the electrical connection of the scale, replace the scale if necessary.

Last updated