Initial commissioning

Description of the initial commissioning (device calibration and priming); work steps which can also be used for troubleshooting.

The DYNCO 2.0 switches on automatically as soon as it is connected to a 12 V DC (vehicle battery).

Calibration of the MOTOREX DYNCO 2.0

If the canisters supplied by MOTOREX are not used, the device or the corresponding scale in the device must be recalibrated using the replacement canister.

Avoid jolting or moving the DYNCO 2.0 during calibration

  • Select the scale that you want to calibrate.

  • Make sure that an empty canister is on the corresponding scale.

  • Confirm by pressing "START".

  • Wait for the calibration to complete and then confirm with "OK"

Calibration menus for the three scales of the DYNCO 2.0
Confirm that calibration can begin.
Display, calibration complete.

To prevent air from entering the DYNCO circuit, PRE-FLUSH can be filled into the additive canister (approx. 1 cm) before the scale is calibrated.

Priming

  • To vent the device or to flush the lines of the MOTOREX DYNCO 2.0, select the menu item "PRIMING" under Settings.

  • Route the fresh oil hose (blue) to the waste oil canister.

  • Start the flushing program.

For a resistance-free flow, use an open adapter from the red case.

  • The "PRIMING" programme runs through the hose rinse in about 15 seconds. After this time has elapsed, you will be prompted to insert the waste oil hose into the waste oil canister and start the second flush.

  • At the end of the oil type change, the completion is acknowledged.

Priming
Starting the hose flushing
Time display for hose flushing